Thursday, April 4, 2019
Occlusion and Occlusal Indicating Materials
Occlusion and Occlusal Indicating MaterialsAbstractIn dentistry it is important for us to understand layover and errors produced during written text it. Over the years many occlusion examination materials gain been employ. The correct occlusion posses as often a challenge for dentist and technician. High spots measuring just a few microns bathroom cause dysfunctions like temporo-mandibular pain. The purpose of this review is to discuss the variant occlusal indicator materials and make us puff up awargon of different advantages and disadvantages of each that will help us to chose the occlusal indicating material.Key words occlusion, occlusal indicator material, occlusal interference, occlusal collisionIntroductionThe alignment and occlusion of the dentition ar extremely important for mastication. as per JPO occlusion is the static family sex actship of the dentition and is basic to all aspects of dentistry. The activities of chewing, swallowing and speaking greatly depend not only on their intra arch position but also on the inter arch tooth position.1 FIG-1Occlusal turn overs are subjected to constant change. tooth restoration, declension and prosthetic care always change the occlusal proportions.An occlusal interference of only few microns can trigger terrible dysfunction. In order to avoid any unpleasant sensation, dealering to temporomandibular joint pain and myalgia various materials and methods have been utilise to detect occlusal interferences. Achieving occlusal signalings over some restorations such as gold, metal alloys and ceramics and on dampish occlusal surfaces has been a difficult task.2Classification of tooth-contact patternsThe tooth contact patterns were classified into tetradgroups as follows2Cuspid saved occlusion.3Canine guidance can be used successfully in over(p) denture discourse as it bids better mandibular denture retention, esthetic appearance, and chewing ability.Group function occlusion4Group function as multip le contact relations between maxillary and mandibular odontiasis in lateral movements on the workings side whereby simultaneous contact of several teeth acts as a group to distribute occlusal forces. The group function of the teeth on working side distributes the occlusal load. The patent advantage is maintenance of the occlusion. The group function philosophy appears to be one of the physiologic wear. Several authors have suggested that occlusal wear is a natural, beneficial and inevitable in a healthfuldeveloped occlusion.Group function of working side is indicated whenever the arch relationship does not allow the anterior guidance to do its job of disoccluding the nonfunctioning side.3. all-inclusive equilibrate occlusion5balanced occlusion comprises realization of tooth contacts at theworking side as well as at the balancing side, at the alike(p) time.The aim of this study was to assess the influence of balanced occlusal arrangement of artificial teeth on the decrease in re-duction of edentulous alveolar ridge. Balanced occlusion is a favored occlusal design in setting of artificial teeth in conventional fatten dentureswhich preserves edentulous ridge and influence the stability of dentures. Influence of balanced occlusion in complete dentures on the decrease in the reduction of an edentulous ridge. 5There are 138 possible contacts in the dentitionwith normal occlusion. 90% of the total units actually make exact contact in dentitions with normal occlusion.2Methods of evaluationg occlusal relationship2Methods of evaluationg occlusal relationship can be of two types-1) Qualitative methods2) Quantitative methodsBoth qualitative and quantitative methods are used for the evaluation of occlusion. In the qualitative method, only the localization of the occlusal contact points can be determined the rank or density of the contacts cannot be evaluated. With the quantitative method of evaluating occlusal relationships, the sequence and density of the contact s can be differentiated.Materials used as occlusal indicatorVarious materials used as an occlusal indicator are as follows2 FIG- 2T-Scan, Pressure Sensitive Films, Alginate Impression MaterialTransparent acetate sheets, Black Silicone,Mylar paper strip,cPolyether rubber imprint bites,Wax Articulation Paper,Occlusal SpraysPhoto occlusion, Foils ,Occlusal SonographyMylar Paper / Shimstock considers6,7The shim stock was positioned over the tooth evaluated. When the participants close in Intercuspal Position, teeth place the shimstock were considered to have occlusal contact with their opposites. Anderson et al. 6reported on the dependability of dentists ability to evaluate occlusal contacts in the intercuspal position. Shim stock and an articulating film were compared in the evaluation of occlusal contacts of 337 antagonist occlusal pairs in 24 young adults by two examiners. Shim stock displayed better reliability than articulating film and appeared suitable for clinical measureme nt of occlusal contacts in intercuspal position.6,7.Polyether occlusal indicator 8Durbin and Sadowsky described a silicone impression material method for examining occlusal contact patterns. The locations of the contacts were then transferred to study role modelsAlginate Impression Material 9 descend and location of perforations were registered as occlusal tooth contacts for each subject. The observed perforations were analyzed according to the frequency of occlusal contacts. Most subjects had asymmetric distribution in number and location of occlusal contactsTransparent Acetate Sheet10It is based on occlusal sketch technique that aimed to provide a simple and reliable means of recording and transferring information about the location of mark occlusal contacts. The authors marked static occlusal contacts of 20 sets of models were put d stimulate in a pseudo-clinical situation, by three dentists and in addition by one dentist on two occasions using a schematic representation of th e dental arch the occlusal sketch. As per Daves et al the occlusal sketch is a simple, inexpensive and easy way of recording the results of an occlusal interrogatory using marking text file.Articulating paper11Articulating papers are used to detect high spots, the width, weightiness and dye type of the articulating paper helps it to leave a mark . The color coating of many articulating papers consists of jump ones, oils and pigments, a hydrophobic mixture which repels saliva. High spots can be detected easily as dark marks and contacts as light marks. The disadvantages of articulating papers have been that they can be affected by saliva, are thick and have a relatively inflexible base material all of these factors bear to greater number of pseudo contact markings . In the in vitro part of the study, a test model (mounted in an articulator and in a universal testing machine) was established with the use of maxillary and mandibular dentate casts. Articulating papers, foils, sil k strips, and the T-Scan system were used to examine the loss of sensitivity of the recording materials after 3 consecutive strokes. The differences in the contact points of the test model determined by each of the recording materials were evaluated both in the articulator and in a universal testing machine. Authors concluded that multiple use of the recording materials tested may lead to inaccurate occlusal compendium results. It is recommended that the recording materials be used only once and that the teeth be run dry during occlusal analysis.Foil12Foils are the thinnest indicator materials. Their marking capacity is less evident under reduced pressure and on glossy surfaces,Thus greater pressure must be applied for application of foils . Authors studied the recording patterns of four foils, six paper materials, and four silk qualities at different pressures and surface morphologies. They concluded that Foils are the thinnest indicator materials and interrupt more accurate rea dings than paper and silk. However, under smaller loads their marking capacity is worse. This means that high pressures must be applied for the clinical use of foils. The drawbacks of the more intensively marking papers and silk are their greater thickness and less flexible base material. This leads to a greater number of pseudo contact markings.12Wax13As per authors articulating papers, particularly plastic strips and waxes, are the most commonly used materials. Occlusal contacts can be recorded by placing the wax on the occlusal surfaces of the maxillary posterior teeth and patient closing into maximum intercuspation. The wax occlusal records was examined in front of a light screen. disadvantages are inaccuracy and problems of manipulationOcclusal Sprays2It can be challenging to mark an occlusal contact on glazed ceramic restorations. Untreated articulating paper does not leave a mark, necessitating the wish for an alternate technique. Articulating ink ribbons leave smudge marks and inaccurate readings. Articulating sprays are easier alternative in these cases .They are easy to administer (Arti-Spray, Bausch articulating paper Inc, Nashua, NH, USA) and leaves a thin colored film which can easily be removed with water, leaving no residues. They are applied at a distance of 3-5 cm onto the occlusal surface. When testing occlusion all contact points will be immediately visible. These are available in colourize red, blue, green and white.Photo-Occlusion14In this system, a thin photoplastic film layer is applied on the occlusal surface of the teeth the patient then is asked to occlude on the film layer. The film layer is removed from the mouthand inspected under a polariscope light. . The results were transferred to a graphic occlusal scheme.Authors designed the study to test clinically the reproducibility of techniques by comparability two consecutive occlusal records and records made at 1-month intervals and to test the reproducibility of a color-marking tec hnique under the same conditions, and to compare the location of occlusal contacts as registered by these two techniques.Occlusion Sonography15It detects tooth contact by the sounds generated during mouth plosive speech sound .The relationship between graphic records of sounds of occlusion and the types of tooth contact which produced them was investigated by the authors by filming various types of occlusal contacts with a Fastax rotating prism camera at approximately 1,000 frames per second.the sliging of the teeth over each other was seen on the flims as low amplitude vibrations and the tooth impacts as high amplitude one.T-Scan16The T-Scan instrument was designed to examine and record occlusal contacts by computer analysis of information from a pressuresensitive film. The T-Scan system digitally record both the location and clock of tooth contacts. The tooth contact information is presented by demonstrating moments of time in the sagittal axis and transverse axis of the occlusal plane. galvanic resistance develops with the applied force. When the patient occludes on the sensor, the particles come together in the force applied areas, decrease the electrical resistance.T Scan system demonstrates sufficient sensitivity and specificity as a diagnostic gumshoe and reliability in intra oral conditions with presence of saliva.It provides registration of dynamic occlusal information.16Pressure Sensitive Films17This thingamajig records the location and force of occlusal contacts with the force sensitive film.An occlusal diagnostic system dental prescale system, Fuji photo film ,Tokyo has recently been developed in japan. This system uses improved pressure sensitive sheets and a computer for analysis to make simple measurements of occlusal contact areas and occlusal pressuresOcclusion and periodontal healthOcclusion has a major relation to the periodontal health of the teeth in oral cavity. A traumatic occlusion on a healthy periodontium causes increased mobility of the tooth,occurrence of gingival recession ,in implants there is breakdown of osseointegration. If a tooth do not its antagonist then there is functional atrophy of periodontal ligament.ConclusionEvery occlusal indicator material has its own advantages and disadvantages. The decision about the use of all the materials depends upon the clinical situation, affordability, reliability and thorough knowledge about materials by the clinician
Subscribe to:
Post Comments (Atom)
No comments:
Post a Comment